      Article summary

      Nexplanon is a small rod inserted into the arm to help prevent pregnancy (more than 99% effective). This effect is reversed by removing the rod.

      In advance (Huddle)

      • MA to confirm supplies needed with provider.

      Glove size:

                                 

      Other requests:



      PPE

      • Sterile gloves

      Setup (MA)

      • Complete demographics portion of consent form.
      • If reinsertion planned, complete urine pregnancy test and document results in EHR.
      • Verify if allergy to iodine or Betadine.
      • Ensure all supplies are available and in procedure room.

      For sterile field

      • Derm Procedure Pack
        • Tissue forceps
        • Straight Kelly forceps
        • Straight mosquito forceps
        • Curved mosquito forceps
        • Iris scissors
        • Needle holder
        • Fenestrated sterile drape
        • Gauze 4x4s (sterile)
      • Scalpel, #11 blade

      Prepped on non-sterile counter

      • Consent form (demographics completed)
      • Sterile gloves (size above)
      • Chux (procedure underpad)
      • If reinsertion planned: Nexplanon package/ device
      • Plastic ruler (for measuring post-extraction length)
      • Surgical marker
      • Betadine swabs
        •  Substitute Chloraprep swabs if allergic to iodine or Betadine.
      • Alcohol pads
      • Syringe, 5 mL
      • Needle, 18 g x 1” (for drawing medicine)
      • Needle, 25 g x 1 1/2” (for administering)
      • Lidocaine 1% with epinephrine
        • If device removal only: 0.5 to 1 mL
        • If reinsertion planned: use 2mL
      • Dressing supplies
        • Steri-strips thin (1/4” x3”) & thick (1/2” x4”)
        • Sterile gauze 4x4
        • Gauze wrap (type? size?)
        • Bandage scissors

      Procedure (Provider)

      Before

      • After reviewing procedure with patient, have patient sign consent form.
      • If reinsertion planned, confirm results of pregnancy test.
      • Using sterile technique, place appropriate items on sterile field.
      • Confirm allergies.
      • Perform time out immediately before procedure.

      After

      • Remove all sharps from work stand and place in sharps container. 
        • Do not delegate this task.

      Was this article helpful?

      What's Next
      Changing your password will log you out immediately. Use the new password to log back in.
      First name must have atleast 2 characters. Numbers and special characters are not allowed.
      Last name must have atleast 1 characters. Numbers and special characters are not allowed.
      Enter a valid email
      Enter a valid password
      Your profile has been successfully updated.